COMMAND
DEFINITION
CODE
COMMAND
VALUE
EXAMPLE
ONLY for EKB3! - Arm all 4 par-
titions simultaneously/ Disarm
and turn OFF the alarm in all 4
partitions simultaneously
0 uumm uumm – 4-digit user/
master code.
0 2222
Set Alarm duration 10 tt # tt – alarm duration, range –
[00... 10] minutes.
1007#
Disable Periodic Info SMS 110000# 110000#
Set Periodic Info SMS
frequency and time
11it f # it – time, range – [01... 23];
f – frequency, range –
[00... 125] days
110412#
Disable/ Enable system con-
trol from any phone number
120 #/ 121 # 120 #/ 121 #
Set SMS password 14 ssss # ssss – 4-digit new SMS
password; range –
[0001... 9999].
141111#
Set installer code 16 iiii # iiii – 4-digit new installer
code; range – [0000... 9999]
162538#
Add user phone number 17 up ttteeellnnuumm # up – user phone number slot,
range – [01... 10]; ttteeelln-
nuumm – up to 15 digits user
phone number.
17010044170911XXXX1#
Enable/Disable Allow adding
new iButton keys mode
18 0 #/ 18 1 # 18 0 #/ 18 1 #
Clear tamper fault 22 # 22#
Disable/ Enable MS mode 230# / 231# 230# / 231#
Disable/Enable Burglary
alarm/restore data message
24010 #/ 24011 # 24010 #/ 24011 #
Disable/Enable Mains
power loss/restore
data message
24020 #/ 24021 #
Disable/Enable Armed/
disarmed by user
data message
24030 #/ 24031 #
Disable/Enable Test
event data message
24040 #/ 24041 #
Disable/Enable Battery
failed data message
24050 #/ 24051 #
Disable/Enable Battery dead
or missing/battery connec-
tion restore data message
24060 #/ 24061 #
Disable/Enable Tamper
alarm/restore data message
24070 #/ 24071 #
Disable/Enable Instant
Silent zone alarm/re-
store data message
24080 #/ 24081 #
Disable/Enable Kronos
ping data message
24090 #/ 24091 #
Disable/Enable System
started data message
24100 #/ 24101 #