ESIM384 Installation and Conguration Manual v1.1
Set user code
EKB2
Menu path:
User code 2... 16: OK mmmm OK CODES OK USER CODE (2-16) OK USER CODE
2... 16 OK CODE OK uuuu OK
User code 17... 30: OK mmmm OK CODES OK USER CODE (17-30) OK USER
CODE 17... 30 OK CODE OK uuuu OK
Value: mmmm – 4-digit master code; uuuu – 4-digit user code, range – [0000... 9999].
EKB3/
EKB3W/
EWKB4
Press , 0, enter master code, user code slot and user code:
0 mmmm us uuuuu #
Value: mmmm - 4-digit master code; us - user code slot, range - [02... 30]; uuuu - 4-digit user
code, range - [0000... 9999].
Example:
01111092556#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Delete user code
EKB2
Menu path:
OK mmmm OK CODES OK REMOVE CODE OK uuuu OK
Value: mmmm – 4-digit master code; uuuu – 4-digit user code.
EKB3/
EKB3W/
EWKB4
Press , 0, enter master code and user code slot:
0 mmmm us #
Value: mmmm - 4-digit master code; us - user code slot, range - [02... 30].
Example:
0111109#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
NOTE: The system does not allow to set a duplicate code.
The user codes ranging from User code 2 through 10 can be set as SGS (Security Guard Service) code, which is used as a checkpoint by a
security service guard upon his/her visit in the secured location. When used, a data message, containing a certain event code, will be deliv-
ered to the monitoring station. However, NO system arming or disarming will be carried out after entering the SGS code.
Set SGS code
EKB2
Menu path:
OK mmmm OK CODES OK SGS CODE OK N/A | USER CODE 2... 10 OK
Value: mmmm – 4-digit master code; N/A – SGS code not in use.
EKB3/
EKB3W/
EWKB4
Press , 4, enter user code slot and enter master code:
4 us mmmm #
Value: us - user code slot, range - [02... 10]; mmmm - 4-digit master code.
Example:
4041111#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
The Duress code is used when system arming or disarming is demanded by force. When used, the system will arm/disarm as well as it will
silently transmit an alert to the monitoring station. Only one of the user codes ranging from User code 2 through 10 can be set as Duress code.
Set Duress code
EKB2
Menu path:
OK mmmm OK CODES OK DURESS CODE OK N/A | USER CODE 2... 10 OK
Value: mmmm – 4-digit master code; N/A – Duress code not in use.
EKB3/
EKB3W/
EWKB4
Press , 3, enter user code slot and master code:
3 us mmmm #
Value: us - user code slot, range - [02... 10]; mmmm - 4-digit master code.
Example:
3081111#