ESIM384 Installation and Conguration Manual v1.1
Turn ON PGM output/
Set PGM output start-
up state as ON
SMS
SMS text message content:
ssss_Coo:ON or ssss_out-name:ON
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 80]; out-name
up to 16 characters PGM output name.
Example: 1111_Lights:ON
EKB2
Menu path:
OK mmmm OK PGM OUTPUTS OK out-name ON OK
Value: mmmm – 4-digit master code; out-name – up to 16 characters PGM output name.
EKB3/
EKB3W/
EWKB4
Enter parameter 61, PGM output number and parameter status value:
61 oo 1 #
Value: oo – PGM output number, range – [01... 80].
Example: 61031#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
EWK1/
EWK2
This operation may be carried out from the wireless keyfob if pre-assigned using the PC run-
ning ELDES Conguration software.
Turn OFF PGM output/
Set PGM output start-
up state as OFF
SMS
SMS text message content:
ssss_Coo:OFF or ssss_out-name:OFF
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 80]; out-name
up to 16 characters PGM output name.
Example: 1111_C2:OFF
EKB2
Menu path:
OK mmmm OK PGM OUTPUTS OK out-name OFF OK
Value: mmmm – 4-digit master code; out-name – up to 16 characters PGM output name.
EKB3/
EKB3W/
EWKB4
Enter parameter 61, PGM output number and parameter status value:
61 oo 0 #
Value: oo – PGM output number, range – [01... 80].
Example: 61020#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
EWK1/
EWK2
This operation may be carried out from the wireless keyfob if pre-assigned using the PC run-
ning ELDES Conguration software.
To instantly turn ON an individual PGM output for a determined time period and automatically turn it OFF when the time period expires,
please refer to the following conguration method.
Turn ON PGM output
for time period
SMS
SMS text message content:
ssss_Coo:ON:hr.mm.sc or ssss_out-name:ON:hr.mn.sc
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 80]; out-name
– up to 16 characters PGM output name; hr – hours, range – [00... 23]; mn – minutes, range
– [00... 59]; sc – seconds, range – [00... 59].
Example: 1111_C4:ON:10.15.35
EWK1/
EWK2
This operation may be carried out from the wireless keyfob if pre-assigned using the PC run-
ning ELDES Conguration software.