ESIM384 Installation and Conguration Manual v1.1
Disable
interconnection
EKB2
Menu path:
OK iiii OK PRIMARY SETT INGS OK SIREN SETTINGS OK EWF1 SIREN INTERC.
OK DISABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 50 and parameter status value:
50 0 #
Example: 500#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Enable
interconnection
EKB2
Menu path:
OK iiii OK PRIMARY SETT INGS OK SIREN SETTINGS OK EWF1 SIREN INTERC.
OK ENABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 50 and parameter status value:
50 1 #
Example: 501#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Set EWF1/EWF1CO
siren alarm duration
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
NOTE: The maximum supported EWF1/EWF1CO siren alarm duration is 255 seconds (4 mins. 15 secs.) even if the system‘s alarm duration value
is longer.
NOTE: System‘s alarm duration has a higher priority against the EWF1/EWF1CO siren alarm duration, therefore EWF1/EWF1CO will sound
as long as the system‘s alarm duration set up, unless the set up value for EWF1/EWF1CO siren alarm duration is shorter.