EasyManua.ls Logo

Emerson Rosemount 2460 System Hub - Inventory Register Area

Emerson Rosemount 2460 System Hub
240 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
198
Modbus
®
Standard Question
Modbus
®
Standard Question
October 2018
Reference Manual
00809-0100-2460, Rev DE
F.4.3 Inventory register area
Table F-6. Inventory Register Area
Register
Number
Register Name Type Unit Description
Inventory Register Area
35200 Observed Density DOUBLE kg/m
3
, API Priority 3 question
35456 Reference Density DOUBLE kg/m
3
, API
35712 CTPL DOUBLE Correction for temperature and pressure
of the liquid used to convert Observed
Density to Reference Density.
36736 Flow Rate DOUBLE m
3
/h, bbl/h Priority 1 question
36992 Free Water Volume DOUBLE m
3
, bbl
37248 Total Observed Volume DOUBLE m
3
, bbl
37504 Available Volume Room DOUBLE m
3
, bbl
37760 Pumpable Volume DOUBLE m
3
, bbl
38016 Tank Shell Temperature
Correction
DOUBLE
38272 Floating Roof Adjustment DOUBLE m
3
, bbl
38528 Gross Observed Volume DOUBLE m
3
, bbl
38784 Gross Standard Volume DOUBLE m
3
, bbl
39040 Net Standard Volume DOUBLE m
3
, bbl
39296 Weight in Air DOUBLE ton (m)
39552 Weight in Vacuum DOUBLE ton (m)
39808 Vapor Liquid Volume DOUBLE m
3
, bbl Vapor converted to liquid volume for LPG
tank
40064 Vapor Mass DOUBLE ton (m) Vapor weight for LPG tank
40320 Product Mass DOUBLE ton (m) Product weight for LPG tank

Table of Contents