160 Specifications and Reference Data
Specifications and Reference Data
October 2018
Reference Manual
00809-0100-2460, Rev DE
A.2 Electrical specifications
A.2.1 Power supply
24-48 VDC (-15%, +10%)
100-250 VAC (-15%, +10%), 50/60 Hz (±2%)
A.2.2 Power consumption
Maximum 20 W
A.2.3 Cable entries
Nine M20 x 1.5
Two M25 x 1.5
A.2.4 Electrical interface
See Table A-3 on page 157, Table A-4 on page 157, and Table A-5
on page 158.
A.2.5 Cable size
Power: 0.75 to 2.1 mm² (18-14 AWG)
Bus: 0.5 to 2.5 mm² (20-14 AWG) depending on communication
interface
A.2.6 Built-in mains fuses
T1.6 A
A.2.7 Backup battery
3V CR 1632 lithium
A.3 Mechanical specifications
A.3.1 Housing material
Polyurethane-covered die-cast aluminum
A.3.2 Installation
Wall mounted by four screws. For further information see
“Dimensional drawings” on page 161.
A.3.3 Weight
7 kg (15 lbs)
A.4 Environmental specifications
A.4.1 Temperature limits
Ambient temperature
-40 to +70 °C (-40 to 158 °F)
Storage temperature
-40 to +80 °C (-40 to 176 °F)
A.4.2 Humidity limits
0-100% relative humidity
A.4.3 Ingress protection
IP 65
A.5 Additional specifications
A.5.1 Metrology sealing possibility
Yes
A.5.2 Write protection
Yes, via software configuration and/or hardware switch.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 2460 System Hub and is the answer not in the manual?

Emerson Rosemount 2460 System Hub Specifications

General IconGeneral
BrandEmerson
ModelRosemount 2460 System Hub
CategorySwitch
LanguageEnglish

Related product manuals