Configuration
October 2018
Configuration
4.3.6 System setup
The System Values window lets you specify parameters and units for inventory calculations.
1. Log in to the Web interface as described in “Using the web interface” on page 114.
2. Select Configuration>System Values.
Figure 4-7. System Parameters and Units
Manual values
Select the appropriate check boxes in case you like to use manual values for ambient air temperature and
pressure, and type the desired values into the input fields.
Reference temperature
The Rosemount 2460 System Hub performs inventory calculations according to the API Manual of
Petroleum Measurement Standards Chapter 12, Section 1, at the standard reference temperature 15°C
(60°F). This is the default reference temperature.
Other reference temperatures can be specified in the Reference Temperature input field. Ensure that
correct RT volume table, for example 54B-2004, is used for the product.
System units
Level, Level Rate, Temperature, and Pressure units are configured in TankMaster WinSetup configuration
program.