Proline t-mass I 300 HART Technical data
Endress+Hauser 183
Cable entries/cable glands
1
2
3
A0020640
 46 Possible cable entries/cable glands
1 Female thread M20 × 1.5
2 Cable gland M20 × 1.5
3 Adapter for cable entry with female thread G ½" or NPT ½"
Order code for "Housing", option A "Aluminum, coated"
The various cable entries are suitable for hazardous and non-hazardous areas.
Cable entry/cable gland Material
Compression fitting M20 × 1.5
Non-Ex: plastic
Z2, D2, Ex d/de: brass with plastic
Adapter for cable entry with female thread G ½" Nickel-plated brass
Adapter for cable entry with female thread NPT ½"
Materials for insertion tube
Stainless steel, 1.4404 (316/316L)
Process connections, process coupling
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Ferrules
PEEK
PVDF
1.4404 (316/316L)