Levelflex FMP55 HART Basic safety instructions
Endress+Hauser 15
2.6.1 Ex-marking in case of connected FHX50 remote display
If the device is prepared for the remote display FHX50 (product structure: feature 030:
Display, Operation", option L or M), the Ex marking of some certificates changes according
to the following table
1)
:
Feature 010 ("Approval") Feature 030 ("Display, Operation") Ex-marking
BG L, M or N ATEX II 3G Ex nA [ia Ga] IIC T6 Gc
BH L, M or N ATEX II 3G Ex ic [ia Ga] IIC T6 Gc
B3 L, M or N ATEX II 1/2G Ex d [ia] IIC T6 Ga/Gb,
ATEX II 1/2D Ex ta [ia Db] IIIC Txx°C Da/Db
IG L, M or N IECEx Ex nA [ia Ga] IIC T6 Gc
IH L, M or N IECEx Ex ic [ia Ga] IIC T6 Gc
I3 L, M or N IECEx Ex d [ia] IIC T6 Ga/Gb,
IECEx Ex ta [ia Db] IIIC Txx°C Da/Db
1) The marking of certificates not mentioned in this table are not affected by the FHX50.