Operating menu Levelflex FMP55 HART
206 Endress+Hauser
Additional information The switch status assumes the value defined in this parameter. This helps to check correct
operation of connected control units.
Device alarm simulation
Navigation Expert → Diagnostics → Simulation → Device alarm simulation
Description Switch the device alarm on and off.
Selection • Off
• On
Factory setting Off
Additional information When selecting the On option, the device generates an alarm. This helps to check the
correct output behavior of the device in the case of an alarm.
An active simulation is indicated by the diagnostic message C484 Failure mode
simulation.
Diagnostic event simulation
Navigation Expert → Diagnostics → Simulation → Diagnostic event simulation
Description Select the diagnostic event to be simulated. Note: To terminate the simulation, select 'Off'.
Factory setting Off
Additional information When operated via the local display, the selection list can be filtered according to the event
categories (Diagnostic event category parameter).