Operating menu Levelflex FMP55 HART
152 Endress+Hauser
Meaning of the options
None
The level is transmitted in the level unit without linearization.
Linear
The output value (volume/weight) is directly proportional to the level L. This is valid, for
example, for vertical cylinders. The following additional parameters have to be specified:
Unit after linearization (→  152)
Maximum value (→  154): Maximum volume or weight
Table
The relationship between the measured level L and the output value (volume/weight) is
given by a linearization table consisting of up to 32 pairs of values "level - volume" or
"level - weight", respectively. The following additional parameters have to be specified:
Unit after linearization (→  152)
Table mode (→  155)
For each table point: Level (→  157)
For each table point: Customer value (→  157)
Activate table (→  157)
Pyramid bottom
The output value corresponds to the volume or weight in a silo with pyramid bottom.
The following additional parameters have to be specified:
Unit after linearization (→  152)
Maximum value (→  154): Maximum volume or weight
Intermediate height (→  155): The height of the pyramid
Conical bottom
The output value corresponds to the volume or weight in a tank with conical bottom. The
following additional parameters have to be specified:
Unit after linearization (→  152)
Maximum value (→  154): Maximum volume or weight
Intermediate height (→  155): The height of the conical part of the tank
Angled bottom
The output value corresponds to the volume or weight in a silo with an angled bottom.
The following additional parameters have to be specified:
Unit after linearization (→  152)
Maximum value (→  154): Maximum volume or weight
Intermediate height (→  155): Height of the angled bottom
Horizontal cylinder
The output value corresponds to the volume or weight in a horizontal cylinder. The
following additional parameters have to be specified:
Unit after linearization (→  152)
Maximum value (→  154): Maximum volume or weight
Diameter (→  154)
Sphere
The output value corresponds to the volume or weight in a spherical tank. The following
additional parameters have to be specified:
Unit after linearization (→  152)
Maximum value (→  154): Maximum volume or weight
Diameter (→  154)
Unit after linearization
Navigation  Setup → Advanced setup → Linearization → Unit after linearization
Prerequisite Linearization type (→  151) ≠ None
Description Select unit of the lineaized value.