Levelflex FMP55 HART Incoming acceptance and product identification
Endress+Hauser 19
4.2.1 Nameplate
20
21
22
24
25
23
26
1
2
3
4
5
6
7
8
9
10
19
18
17
16
15
14
Ext. ord. cd.:
Order code:
Ser. no.:
LN =
Lref =
Mat.:
Date:
FW:
Dev.Rev.:
DeviceID:
Ta:
if modification
see sep. label
X =
MWP:
12
11
47 (1.85)
92 (3.62)
13
A0010725
 3 Nameplate of the Levelflex; Dimensions: mm (in)
1 Device name
2 Address of manufacturer
3 Order code
4 Serial number (Ser. no.)
5 Extended order code (Ext. ord. cd.)
6 Process pressure
7 Gas phase compensation: reference distance
8 Certificate symbol
9 Certificate and approval relevant data
10 Degree of protection: e.g. IP, NEMA
11 Document number of the Safety Instructions: e.g. XA, ZD, ZE
12 2-D matrix code (QR code)
13 Modification mark
14 Manufacturing date: year-month
15 Permitted temperature range for cable
16 Device revision (Dev.Rev.)
17 Additional information about the device version (certificates, approvals, communication): e.g. SIL, PROFIBUS
18 Firmware version (FW)
19 CE mark, C-Tick
20 DeviceID
21 Material in contact with process
22 Permitted ambient temperature (T
a
)
23 Size of the thread of the cable glands
24 Length of probe
25 Signal outputs
26 Operating voltage
Only 33 digits of the extended order code can be indicated on the nameplate. If the
extended order code exceeds 33 digits, the rest will not be shown. However, the
complete extended order code can be viewed in the operating menu of the device in
the Extended order code 1 to 3 parameter.