EasyManua.ls Logo

Endress+Hauser Levelflex FMP55 - Assign Channel 1 to 4; Data Logging; Data Logging Submenu; Measured Current

Endress+Hauser Levelflex FMP55
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP55 HART Operating menu
Endress+Hauser 199
17.5.5 "Data logging" submenu
Navigation  Diagnostics → Data logging
Assign channel 1 to 4
Navigation  Diagnostics → Data logging → Assign channel 1 to 4
Description Assign a process variable to logging channel.
Selection Off
Level linearized
Distance
Unfiltered distance
Interface linearized
*
Interface distance
*
Unfiltered interface distance
Thickness upper layer
*
Current output 1
Measured current
Current output 2
*
Terminal voltage
Electronic temperature
Measured capacitance
*
Absolute echo amplitude
Relative echo amplitude
Absolute interface amplitude
*
Relative interface amplitude
*
Absolute EOP amplitude
EOP shift
Noise of signal
Calculated DC value
*
Analog output adv. diagnostics 1
Analog output adv. diagnostics 2
Factory setting Off
Additional information A total of 1000 measured values can be logged. This means:
1000 data points if 1 logging channel is used
500 data points if 2 logging channels are used
333 data points if 3 logging channels are used
250 data points if 4 logging channels are used
If the maximum number of data points is reached, the oldest data points in the data log
are cyclically overwritten in such a way that the last 1000, 500, 333 or 250 measured
values are always in the log (ring memory principle).
The logged data are deleted if a new option is selected in this parameter.
* Visibility depends on order options or device settings

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP55

Related product manuals