Levelflex FMP55 HART Mounting
Endress+Hauser 25
6.1.4 Mounting cladded flanges
Use flange screws according to the number of flange holes.
Tighten the screws with the required torque (see table).
Retighten the screws after 24 hours or after the first temperature cycle.
Depending on process pressure and process temperature check and retighten the
screws at regular intervals.
Usually, the PTFE flange cladding also serves as a seal between the nozzle and the
device flange.
Flange size Number of screws Recommended torque [Nm]
minimum maximum
EN
DN40/PN40 4 35 55
DN50/PN16 4 45 65
DN50/PN40 4 45 65
DN80/PN16 8 40 55
DN80/PN40 8 40 55
DN100/PN16 8 40 60
DN100/PN40 8 55 80
DN150/PN16 8 75 115
DN150/PN40 8 95 145
ASME
1½"/150lbs 4 20 30
1½"/300lbs 4 30 40
2"/150lbs 4 40 55
2"/300lbs 8 20 30
3"/150lbs 4 65 95
3"/300lbs 8 40 55
4"/150lbs 8 45 70
4"/300lbs 8 55 80
6"/150lbs 8 85 125
6"/300lbs 12 60 90
JIS
10K 40A 4 30 45
10K 50A 4 40 60
10K 80A 8 25 35
10K 100A 8 35 55
10K 100A 8 75 115

Table of Contents