10 Block SPECIAL FUNCTION Device Functions Proline Promass 83 MODBUS RS485
136 Endress+Hauser
AVERAGING DRIP
MODBUS register:
Data type:
Access:
7207
See Note
Float
read/write
! Note!
Function is only available if MODE 1 or MODE 2 is selected in the function
COMPENSATION MODE (7205).
For specifying the number of after run quantities (cycles) which are included in
calculating the batching compensation mode, MODE 1 or MODE 2.
! Note!
The value entered in this function influences the measuring system reaction time.
! Note for MODBUS!
The MOBBUS register depends on the option selected in the function BATCH
SELECTOR (7200):
• BATCH # 1 = MODBUS register 6368
• BATCH # 2 = MODBUS register 6370
• BATCH # 3 = MODBUS register 6372
• BATCH # 4 = MODBUS register 6374
• BATCH # 5 = MODBUS register 6376
• BATCH # 6 = MODBUS register 6378
If you specify:
• a small calculation depth (low value entered) = measuring system reacts
quickly to differing amount of after run quantities.
• a large calculation depth (high value entered) = measuring system reacts slowly
to changing after run quantities.
User input: 0 to 100
Factory setting:: 0 [cycles]
BATCH STAGES
MODBUS register:
Data type:
Access:
7208
See Note
Integer
read/write
For selecting the number of batching stages. Batching can be carried out in several
stages, e.g. 2-stage batching with fast and precise batching.
Options:
0 = 1-stage (1 valve or 1-stage batching)
1 = 2-stage (2 valves or 2-stage batching)
Factory setting: 1-stage (1 valve or 1-stage batching)
! Note!
• The batching stage selection (number of valves) is directly dependent on the
configuration of the outputs. For 2-stage batching two relay outputs must be
available in the measuring device.
• The functions available in the function group VALVE PARAMETER (Page 138)
are dependent on the number of batching stages (number of valves) selected in
this function.
! Note for MODBUS!
The MOBBUS register depends on the option selected in the function BATCH
SELECTOR (7200):
• BATCH # 1 = MODBUS register 6380
• BATCH # 2 = MODBUS register 6381
• BATCH # 3 = MODBUS register 6382
• BATCH # 4 = MODBUS register 6383
• BATCH # 5 = MODBUS register 6384
• BATCH # 6 = MODBUS register 6385
Function description
SPECIAL FUNCTION → BATCHING FUNCTION → CONFIGURATION