PROline Prosonic Flow 93 FOUNDATION Fieldbus 3 Block MEASURED VARIABLES
Endress+Hauser 15
3.2 Group SYSTEM UNITS
3.2.1 Function group: CONFIGURATION
MEASURED
VARIABLES
A
Þ
MEASURED VALUES AAA
ß
SYSTEM UNITS ACA
Þ
CONFIGURATION 040
Function description
MEASURED VARIABLES → SYSTEM UNITS → CONFIGURATION
Use this function group to select the units for the measured variables.
Note!
The units selected here have no effect on the FOUNDATION Fieldbus. They are only used for the local
display and for assigned instrument functions.
UNIT VOLUME FLOW
(0402)
Use this function to select the unit for displaying the volume flow.
The unit you select here is also valid for:
• Simulation
• Low flow cut off
Options:
Note!
The following units of time (...) can be selected:
s = second, m = minute, h = hour, d = day
Metric:
Cubic centimetre
→ cm³/...
Cubic decimetre
→ dm³/...
Cubic metre
→ m³/...
Millilitre
→ ml/...
Litre
→ l/...
Hectolitre
→ hl/...
Megalitre
→ Ml/... MEGA
US:
Cubic centimetre
→ cc/...
Acre foot
→ af/...
Cubic foot
→ ft³/...
Fluid ounce
→ oz f/...
Gallon
→ US gal/...
Million gallon
→ US Mgal/...
Barrel (normal fluids: 31.5 gal/bbl)
→ US bbl/... NORM.
Barrel (beer: 31.0 gal/bbl)
→ US bbl/... BEER
Barrel (petrochemicals: 42.0 gal/bbl)
→ US bbl/... PETR.
Barrel (filling tanks: 55.0 gal/bbl)
→ US bbl/... TANK
Imperial:
Gallon
→ imp. gal/...
Mega gallon
→ imp. Mgal/...
Barrel (beer: 36.0 gal/bbl)
→ imp. bbl/... BEER
Barrel (petrochemicals: 34.97 gal/bbl)
→ imp. bbl/... PETR.
Factory setting: