PROline Prosonic Flow 93 FOUNDATION Fieldbus 3 Block MEASURED VARIABLES
Endress+Hauser 17
3.2.2 Funktion group: ADDITIONAL CONFIGURATION
MEASURED
VARIABLES
A
Þ
MEASURED VALUES AAA
ß
SYSTEM UNITS ACA
Þ
CONFIGURATION 040
ß
ADDIT. CONFIG. 042
Function description
MEASURED VARIABLES → SYSTEM UNITS → ADDITIONAL CONFIGURATION
Note!
The units selected here have no effect on the FOUNDATION Fieldbus. They are only used for the local
display and for assigned instrument functions.
UNIT TEMPERATURE
(0422)
Use this function to select the unit for displaying the liquid temperature.
Note!
The fluid temperature is entered in the TEMPERATURE function, (see
Page 60).
Options:
°C (Celsius)
K (Kelvin)
°F (Fahrenheit)
R (Rankine)
Factory setting:
Depends on country (°C or °F), see factory setting Page 76 ff.
UNIT VISCOSITY
(0423)
Use this function to select the unit for fluid viscosity.
Note!
The viscosity is entered in the VISCOSITY function, (see Page 61).
Options:
mm²/s
cSt
St
Factory setting:
mm²/s
UNIT LENGTH
(0424)
Use this function to select the unit for the measure of length.
The unit you select here is valid for:
• Nominal diameter
• Diameter
• Wall thickness
• Liner thickness
• Path length
• Wire length
• Sensor distance
Options:
MILLIMETER
INCH
Factory setting:
Depends on country (MILLIMETER or INCH),
see factory setting Page 76 ff.