3. Attach the BELT TENSION ATTACHMENT jig to the end of the Push-pull
gauge, and secure it with a screw.
4. Push the CR BELT at the center with the push-pull gauge until the belt comes
in contact with the printer frame so as to measure the tension. Loosen/tighten
the tension adjustment screws until the measured value falls within the
standard range.
5. Apply thread locker to the shaft of the driven pulley and adjustment screws.
Figure 5-14. Measuring Tension
Pay attention not to drop Tread Locker on the belt or it would
prevent the belt from moving smoothly.