Epson Stylus Pro GS6000 Revision F
ADJUSTMENT Clear Counters 233
Confidential
5.7 Clear Counters
Whenever the parts/units which have life counter are replaced, the corresponding life
counter must be reset. This is important to replace those parts/units at the correct
timing.
Procedure
1. Turn the printer ON.
2. Start the Service Program and select a target Counter Reset menu.
3. Press [Run] to reset the counter.
4. Click the [Finish] button.
Figure 5-50. [Clear Counter] Screen
The printer stores the counter reset history up to 10 resets. Be
careful not to reset the counters more than necessary or the older
reset histories will be deleted.
Table 5-2. Clear Counter Menu List
Replaced Part/Unit Menu Name
CR MOTOR CR Motor Life Counter Save & Reset
PF MOTOR PF Motor Life Counter Save & Reset
PRINT HEAD L (1) Head L (M,C,K,Y) Life Counter Save & Reset
PRINT HEAD R (2) Head R (O,G,Lc,Lm) Life Counter Save & Reset
PUMP ASSY 1 Pump Motor 1 (Front) Life Counter Save & Reset
PUMP ASSY 2 Pump Motor 2 (Rear) Life Counter Save & Reset
WIPER ASSY Head Wiping Counter Reset
CLEANER HEAD
Take care when using All Counter Clear in Counter Reset. This
function clears all the counters such as the total operating time or
the like including the parts to be replaced mentioned above.