EasyManua.ls Logo

Epson Stylus Pro GS6000 - CR Reduction Belt Tension Adjustment

Epson Stylus Pro GS6000
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Epson Stylus Pro GS6000 Revision F
ADJUSTMENT CR Related Adjustments 201
Confidential
5.3.2 CR Reduction Belt Tension Adjustment
When the CR MOTOR or the CR Reduction BELT is reattached or replaced, or the CR
Reduction BELT tension is loosened, this adjustment must be carried out to apply
proper tension to the belt.
Required Tool
Push-pull gauge (the one which can measure 3.85 kg)
SONIC Tension Measurement tool U-507 or U-505
Standard value
Push-pull gauge: 3.5kg ± 10%
SONIC: 15~22.5N
Parts need to be removed in advance
TOP COVER R
PANEL COVER
SIDE COVER, R
IH COVER, R
Procedure
1. Loosen the four screws that secure the CR MOTOR.
2. Remove the screws and release the adjustment wire.
3. Attach the gauge to the wire and pull the gauge toward the rear of the printer.
Figure 5-15. CR Reduction Belt Tension Adjustment
4. With the specified value is indicated on the scale of the gauge, tighten the four
screws to secure the CR MOTOR.
C A U T I O N
Make sure to tighten the screws strongly. (target:14N)
Push-pull gauge
Screws
Wire

Table of Contents

Other manuals for Epson Stylus Pro GS6000

Related product manuals