5. Enter the following parameters to the SONIC Tension Measurement tool U-
507.
(Refer to “8.1.1 Sonic Parameters Input” Video.)
MASS: 001.2g/m
WIDTH: 010.0mm/R
SPAN: 006.1mm
Figure 5-16. SONIC Tension Measurement
6. After making sure the CR is in the lock position, measure the belt tension by
putting the SONIC sensor in front of the belt, between the pulley and the motor.
(Refer to “8.1.2 Sonic Measurement” Video.)
Within the range of 15~22.5N:Put a black marking (straight line) on the
pulley center. See Figure 5-18.
Out of the range of 15~22.5N: Repeat the Step 2~Step 6 again.
Figure 5-17. Measurement the CR Reduction Adjustment
Figure 5-18. Putting a black marking on the pulley center
The Service Manual file is linked to the video file with the same
revision letter. The Ch.8 file containing the videos has to be saved in
the same folder as this Service Manual file in order to access it with