Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 155
Confidential
4.4.10 Paper Feed Mechanism
4.4.10.1 PF ENC SCALE
1. Remove the TOP COVER (left only). (p85)
2. Remove the MAINTE COVER T. (p88)
3. Remove the SIDE COVER (left only). (p89)
4. Remove the two screws on the shaft.
A) Silver, Phillips, Pan with S.W & P.W M3x8: two pieces
5. Remove the four screws on the fixing plate and remove the plate.
B) Silver, Phillips, Cup P-tite M3x8: four pieces
6. Remove the PF ENC SCALE drawing it out from the slit of the PF ENCODER
ASSY.
Figure 4-125. Removing the PF ENC SCALE
In the next step, take care not to damage or contaminate the PF
ENC SCALE.
Do not touch the PF ENC SCALE with bare fingers and make
sure your gloves are not stained with ink before touching it.
When installing the PF ENC SCALE, make sure to attach it so that
you can read the letters on it correctly.
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing the PF ENC
SCALE.
<Adjustment item>
1. Encoder Test