Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 156
Confidential
4.4.10.2 PF MOTOR
1. Remove the TOP COVER (left only). (p85)
2. Remove the MAINTE COVER T. (p88)
3. Remove the SIDE COVER (left only). (p89)
4. Disconnect the relay connector.
5. Remove the two screws, and remove the PF MOTOR by drawing out the pinion
gear inward from the PF Timing Belt and the hole.
A) Silver, Phillips, Pan with S.W & P.W M4x8: two pieces
Figure 4-126. Removing the PF MOTOR
When installing the PF MOTOR, make sure to attach it with the
label facing upward as shown in the figure below.
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing the PF Motor.
<Adjustment items>
1. PF Reduction Belt Tension Adjustment
2. PF Counter Reset
3. Paper Feed Adjustment