DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 157
Confidential
4.4.10.3 PRESSURE ROLLER
1. Remove the REAR PAPER GUIDE. (p96)
2. Remove the SPINDLE GUIDE COVER. (p97)
3. Detach the two lower ends of springs from the grooves of the Roller Holder.
4. Disengage the shafts on both ends from the grooves, and remove the Roller
Holder.
Figure 4-127. Removing the PRESSURE ROLLER with the Roller Holder
5. Disengage the shafts on both ends from the grooves, and remove the PRESSURE
ROLLER.
Figure 4-128. Removing the PRESSURE ROLLER
This part is used more than one location, but basically you can
remove any part in the same way. Therefore this section
describes the way to remove one part only.
In Step 3, be careful not to detach the upper end of the springs.
It is difficult to install the upper end in a dim environment.
When removing the Roller Holder, take care not to damage the
Feed Roller.
When replacing a Roller Holder, Make sure it is correctly
lubricated. (See p253 for Lubrication details)