5.3 CR Related Adjustments
5.3.1 CR Belt Tension Adjustment
When the CR MOTOR or the CR BELT is reattached/replaced, or tension of the belt is
loosened, this adjustment must be performed to apply proper tension to the belt.
Required Tool
Push-pull gauge (the one which can measure 110 g)
BELT TENSION ATTACHMENT
Standard value
100 g to 110 g
Parts need to be removed in advance
TOP COVER L
MAINTE COVER T
SIDE COVER, L
Procedure
1. Unlock the Carriage, and move the Carriage to the left end.
?4.4.1.1 Unlocking the Carriage? (p.83)
2. While sliding the Carriage, adjust the CR BELT so that the belt can run in the
middle of the driven pulley by turning the upper and lower adjustment screws.
Figure 5-12. Slant Adjustment of Driven Pulley
Figure 5-13. Adjustment Screws and Thread locker Positions
OK NG NG
CR BELT
Driven pulley
Adjustment screws
Thread locker