Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 123
Confidential
4.4.7 Sensors
4.4.7.1 PF ENCODER ASSY
1. Remove the TOP COVER (left only). (p85)
2. Remove the MAINTE COVER T. (p88)
3. Remove the SIDE COVER (left only). (p89)
4. Remove the REAR PAPER GUIDE. (p96)
5. Remove the SPINDLE GUIDE COVER. (p97)
6. Remove the IH COVER (left only). (p90)
7. Remove the PF ENC SCALE.(p155)
8. Disconnect connector J2 from the SUB_C BOARD ASSY.
9. Release the cable from the two clamps at the rear.
Figure 4-82. Releasing the cable
10. Release the cable from the three clamps and the one retainer on the left side.
11. Remove the two screws.
A) Silver, Phillips, Bind machine screw M2x10: two pieces
12. Press the part beside the pin to disengage the hook behind the sensor, and remove
the PF ENCODER ASSY.
Figure 4-83. Removing the PF ENCODER ASSY
When routing the cable at the rear, make sure to give it one turn
around the marked clamp. See Figure 4-82.