4.4.7.3 CR HP SENSOR
1. Remove the TOP COVER (right only). (p85)
2. Unlock the Carriage. (p83)
3. Disconnect the connector.
4. Disengage the hooks, and remove the CR HP SENSOR.
Figure 4-86. Removing the CR HP SENSOR
C A U T I O N
The CR HP SENSOR is secured with thread-locker. Therefore,
remove the thread-locker when removing the sensor.
Connector
CR HP Sensor
As seen from the top
After installation, make sure to apply thread locker around the
CR HP SENSOR to secure it.
Make sure you set the sensor in the correct direction, connector
on the rear.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Sensor Test
Thread-lock area
As seen from the top