Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 127
Confidential
4.4.7.4 PAPER EDGE SENSOR
1. Remove the TOP COVER (left only). (p85)
2. Remove the MAINTE COVER T. (p86)
3. Remove the SIDE COVER (left only). (p89)
4. Remove the IH COVER (left only). (p90)
5. Unlock the Carriage. (p83)
6. Remove the CR Top Cover (Step 6 to 9 in 4.4.5.3 COOLING FAN). (p104)
7. Disconnect the connector J16 from the SUB_A BOARD ASSY.
8. Release the cable from 4 clamps.
Figure 4-87. Releasing the cable
9. Remove 2 screws that secure the COOLING FAN (left side) bracket.
A) Silver, Phillips, Pan with S.W & P.W M3x6: two pieces
10. Remove a screw to remove the PAPER EDGE SENSOR.
B) Silver, Phillips, Pan with S.W & P.W M3x6: one piece
Figure 4-88. Removing the PAPER EDGE SENSOR