Epson Stylus Pro GS6000 Revision F
ADJUSTMENT Other Adjustments 230
Confidential
5.6.6 Rear Sensor Test/Rear AD Adjustment
5.6.6.1 Rear Sensor Test
This test allows you to test the Paper Rear Sensor.
Procedure
1. Select Sensor => RearAD.
2. Place some paper into the Paper Rear Sensor position (on the middle of the
Pre-heater).
Figure 5-47. Paper Rear Sensor Position
5.6.6.2 Rear AD Adjustment
This function allows you to calibrate the Paper Rear Sensor in the following way.
Procedure
1. Select Adjustment => RearAD.
2. Place some paper into the Paper Rear Sensor position (on the middle of the
Pre-heater).
3. Press the [Enter] button to calibrate the sensor.
NOTE: Some Media may have marks on the reverse side. In such cases, make
sure not to put a dark mark above the sensor or the sensor will not be
able to detect the media.
Figure 5-48. Rear AD Adjustment