DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 99
Confidential
4.4.4 Electric Components
4.4.4.1 FUSE
1. Remove the five screws and open the Elec Box.
A) Silver, Phillips, Pan with S.W & P.W M4x8: five pieces
Figure 4-40. Opening the Elec Box
2. Pry the FUSE out.
Figure 4-41. Removing the FUSE
C A U T I O N
In the next step, the cover will drop open suddenly immediately
after removing the last screw. Therefore, make sure to hold the
cover when removing the last few screws.
A
Elec Box
As seen from the rear bottom
C A U T I O N
When replacing the FUSEs, make sure to use the following fuses
approved and designated by SEIKO EPSON CORPORATION.
Size:
φ
10.3 x 38mm (L)
Rating: 250V-15A
Manufacturer: SATO PARTS CO.,LTD
Model: F-7165
FUSEs