3.3 Remedies for Maintenance Requests
When a Maintenance Request error occurs, the printer displays on the LCD a hexadecimal code of "NNNN" which correspond to the bit numbers assigned to error statuses as shown
in the table below.
Table 3-1. About the Maintenance Request NNNN
Bit assignment (Binary) NNNN
(Hexa-
decimal)
Cause Remedy
1 2 3 4 5 6 7
1 (N/A) 0 (N/A) (N/A) (N/A) 0
0002
The CR scan pass counter has reached the specified value. (CR MOTOR
and INK TUBE are getting close to the end of their life.)
Replace the CR MOTOR (p.151) and the INK TUBE
(p.173) with a new one, perform the necessary adjustments
and clear the counter using the Service Program (p.233).
0 (N/A) 1 (N/A) (N/A) (N/A) 0
0008
The RTC backup battery becomes exhausted. Replace the battery and make the date and time setting
using the service program (p.224).
0 (N/A) 0 (N/A) (N/A) (N/A) 1
0080
The date has not been set. Make the date and time setting using the Service Program
(p.224).
1 (N/A) 1 (N/A) (N/A) (N/A) 0
000A
The CR scan pass counter has reached the specified value (CR MOTOR
and INK TUBE are getting close to the end of their life.) and the RTC
backup battery becomes exhausted.
Refer to the corresponding remedies.
1 (N/A) 0 (N/A) (N/A) (N/A) 1
0082
The CR scan pass counter has reached the specified value (CR MOTOR
and INK TUBE are getting close to the end of their life.) and the date has
not been set.
Refer to the corresponding remedies.
0 (N/A) 1 (N/A) (N/A) (N/A) 1
0088
The RTC backup battery becomes exhausted and The date has not been
set.
Refer to the corresponding remedies.
1 (N/A) 1 (N/A) (N/A) (N/A) 1
008A
The CR scan pass counter has reached the specified value. (CR MOTOR
has reached its end of life.) The RTC backup battery becomes exhausted
and The date has not been set.
Refer to the corresponding remedies.
Description
CR life
Unassigned
Battery exhaustion
Unassigned
Unassigned
Unassigned
Date not set