DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 124
Confidential
When routing the cable on the left side, make sure to secure the
cable with the cable retainer and give it one turn around the
marked clamp as shown in the figure below.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Encoder Test
Retainer
PF ENCODER ASSY
Clamp to turn
As seen from the left