Epson Stylus Pro GS6000 Revision F
ADJUSTMENT CR Related Adjustments 203
Confidential
7. Unlock the CR and move the carriage left and right a few times, the black
mark on the pulley will shift out from the center.
(Refer to “8.1.3 Adjustment Confirmation” Video.)
8. Move the CR Unit to the home position until the black marking (straight line)
on the pulley is located on the same position as in step 6.
9. Measure again the CR Reduction Belt tension.
Within the range of 15~22.5N: The procedure is finished. Go to Step 10.
Out of the range of 15~22.5N: Go to
Step 9-1
to do a minor Adjustment.
9-1. Loosen the four screws that secure the CR Motor.
9-2. Move the Motor slightly by hand.
If the previous measurement showed too much tension, loosen the tension.
If the previous measurement showed too little tension, increase the tension.
9-3. Tighten the four screws on diagonal order.
Figure 5-19. Tighten the four screws
9-4. Move the CR left and right 5,6 times.
9-5. Measure the CR Reduction Belt tension again.
Within the range of 15~22.5N: The procedure is finished. Go to Step 10.
Out of the range of 15~22.5N: Repeat the Step 9-1~Step 9-5 again or
repeat the method again from the Step 1.
10. Return the wire to the original position.