Epson Stylus Pro GS6000 Revision F
ADJUSTMENT Head Related Adjustments 221
Confidential
Figure 5-36. Explanation on the Fine Adjustment Pattern
XXX-D : PG XX
VSDX XXX Fine Head 2 6A MecNo . XXXXXXXXXX Data (YY/MM/DD) xx/xx/xx
-4
2468-2-4-6-8
The upper and lower lines stand as a scale and each of them stands
at two steps. Each time the or button is pressed, two steps are
incremented or decremented.
In the above sample pattern, the best line exists at the second steps leftward
(minus) from the center, so you need to press the button two times.
The current setting
(the pattern is printed placing the current setting to the center)
The best line to be selected
Enlarged viewAdjustment Pattern
<Uni-D Pattern>
<Bi-D Pattern>
XXX-D : PG XX
VSDX XXX Fine Head 2 6A MecNo . XXXXXXXXXX Data (YY/MM/DD) xx/xx/xx
12345678
12345678
Row of A
Row of B