Epson Stylus Pro GS6000 Revision F
ADJUSTMENT Tests 238
Confidential
Fan Test VACUUM FAN
1. Select the menu as follows.
Fan => Paper X*
*: Fan number (there are four vacuum fans)
Visually or acoustically check that the fan is operating.
COOLING FAN (Left)
1. Select the menu as follows.
Fan => Head Fan 1
Visually or acoustically check that the fan is operating.
COOLING FAN (Right)
1. Select the menu as follows.
Fan => Head Fan 2
Visually or acoustically check that the fan is operating.
HEATER BOARD COOLING FAN
1. Select the menu as follows.
Fan => HT Fan
Acoustically or by the air exhausted from the exhaust outlet, check
that the fan is operating.
Alarm LED Test ALARM LED
1. Select the menu as follows.
Panel => Printer Check LED
Check that the LED (Active Indicator) flashes.
Encoder Test CR ENC ASSY
CR ENC SCALE
1. Select the menu as follows.
Encoder
2. Manually move the CR CURSOR ASSY.
1. Check that the CR value indicated on the panel changes according
to the CR CURSOR ASSY position.
2. Determine a base point and move the CR CURSOR ASSY away
and back to the base point to see whether the displayed CR value
returns to the base point displayed value.
PF ENCODER ASSY
1. Select the menu as follows.
Encoder
2. Manually turn the paper feed roller.
Check that the PF value indicated on the panel changes as the roller
is rotated.
PF ENC SCALE
PF MOTOR
PF REDUCTION BELT
Heater Test PRE HEATERS (64)
1. Select the menu as follows.
This test causes the heater temperature to rise to 50 degrees C.
Ctrl. Test => Ctrl. Sns => CtrlSns. Tank => Pre. Heater
Check that the temperature indicated on the panel goes up to 50
degrees C.
PLATEN HEATER (64)
1. Select the menu as follows.
This test causes the heater temperature to rise to 50 degrees C.
Ctrl. Test => Ctrl. Sns => CtrlSns. Tank => Platen. Heater
Check that the temperature indicated on the panel goes up to 50
degrees C.
AFTER HEATER (64)
1. Select the menu as follows.
This test causes the heater temperature to rise to 50 degrees C.
Ctrl. Test => Ctrl. Sns => CtrlSns. Tank => After. Heater
Check that the temperature indicated on the panel goes up to 50
degrees C.
Test Menu Related Parts Procedure Check/Action