Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
F
94 93
TM-T90
Specification
(STANDARD)
[Description] • Sets the position and the size of the printing area.
•
Horizontal starting position = [(x
L
+ x
H
× 256) × (horizontal motion units)].
•
Vertical starting position = [(y
L
+ y
H
× 256) × (vertical motion units)].
•
Horizontal printing area width = [(dx
L
+ dx
H
× 256) × (horizontal motion units)].
•
Vertical printing area width = [(dy
L
+ dy
H
× 256) × (vertical motion units)].
[Note] • The maximum printable area is 117.263 mm {1662/360"} maximum.
ESC \ n
L
n
H
[Name] Set relative print position
[Format] ASCII ESC \ n
L
n
H
Hex 1B 5C n
L
n
H
Decimal 27 92 n
L
n
H
[Range] 0 ≤ (n
L
+ n
H
× 256) ≤ 65535 (0 ≤ n
L
≤ 255, 0 ≤ n
H
≤ 255)
[Description] • Sets the print starting position based on the current position to ((n
L
+ n
H
× 256) × horizontal or
vertical motion units).
•
When (n
L
+ n
H
× 256) is positive number, the print starting position is specified to the right
based on the current position.
•
When (n
L
+ n
H
× 256) is negative number, the print starting position is specified to the left
based on the current position.