EasyManua.ls Logo

Epson TM-T90 - Function 51> GS ( L Pl Ph M Fn (Fn = 3, 51)

Epson TM-T90
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
F
142 141
TM-T90
Specification
(STANDARD)
<Function 51> GS ( L p
L
p
H
m fn (fn = 3, 51)
[Format] ASCII GS ( L p
L
p
H
m fn
Hex 1D 28 4C p
L
p
H
m fn
Decimal 29 40 76
p
L
p
H
m fn
[Range] (
p
L
+
p
H
× 256) = 2 (
p
L
= 2,
pH
= 0)
m = 48
fn
= 3, 51
[Description] Transmits the number of bytes of remaining memory (unused area) in the NV user memory.
Hexadecimal Decimal Amount of data
Header 37H 55 1 byte
Identifier 31H 49 1 byte
Data 30H 39H 48 57 1 8 bytes
NUL 00H 0 1 byte
The number of bytes of remaining memory is converted to character codes corresponding
to decimal data, then transmitted from the MSB.
The data length is variable.

Table of Contents

Other manuals for Epson TM-T90