Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
F
139 138
TM-T90
Specification
(STANDARD)
<Function 97> GS ( K p
L
p
H
fn m (fn = 97)
[Format] ASCII GS ( K p
L
p
H
fn m
Hex 1D 28 4B p
L
p
H
fn m
Decimal 29 40 75 p
L
p
H
fn m
[Range] (p
L
+ p
H
× 256) = 2 (p
L
= 2, p
H
= 0)
fn = 97
0 ≤ m ≤ 6, 48 ≤
m
≤ 52
[Default] m = 0 (setting value of the customized value)
[Description] • Specifies the number of parts for energizing the head.
m Number of divided parts for energizing the head
0, 48
Setting value of
GS ( E
<Function 5:
a
= 97>
1, 49 Selects one-part energizing.
2, 50 Selects two-part energizing.
3, 51 Selects three-part energizing.
4, 52 Selects four-part energizing.