Specification
(STANDARD)
GS ( D p
L
p
H
m [a1 b1]...[ak bk]
[Name] Enable/disable real-time command
[Format] ASCII GS ( D pL pH m [a1 b1]...[ak bk]
Hex 1D 28 44 pL pH m [a1 b1]...[ak bk]
Decimal 29 40 68 pL pH m [a1 b1]...[ak bk]
[Range] 3 (p
L
+ p
H
× 256) 65535 (0 pL 255, 0 pH 255)
m = 20
a = 1, 2
b = 0, 1, 48, 49
[Default]
a Type(s) of real-time commands Default
1
DLE DC4
fn m t (fn = 1): Generate pulse in real time
Enabled (b = 1)
2
DLE DC4
fn a b (fn = 2): Execute power-off sequence
Disabled (b = 0)
[Description] Enables or disables the following real-time commands.
a b Function
0, 48
DLE DC4
fn m t (fn = 1): Not processed (disabled)
1
1, 49
DLE DC4
fn m t (fn = 1): Processed (enabled)
0, 48
DLE DC4
fn a b (fn = 2): Not processed (disabled)
2
1, 49
DLE DC4
fn a b (fn = 2): Processed (enabled)
p
L
, p
H
specifies (p
L
+ p
H
× 256) as the number of bytes after p
H
(m and [a1 b1]…[ak bk]).
a specifies the type of real-time command.
b specifies enabled or disabled.
[Note] If bit image data accidentally includes a character string containing a real-time command, it is
recommended to use this command in advance to disable the real-time commands.