EasyManua.ls Logo

Epson TM-U375 - B Space Adjustment between the Linked Lever and Platen Holder; C Tension Lever Adjustment

Epson TM-U375
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-41
Adjustment B Space Adjustment Between the Linked Lever and Platen Holder
Adjust-
ment
Step
1
2
3
Loosen the Solenoid-Platen switching
securing screw.
Move the Solenoid-Platen switching up
and down to adjust the space between the
Linked lever and Platen holder.
Tighten the screw to secure the solenoid.
Space (A): 9.3 ± 0.2 mm (0.37 ± 0.008")
Adjust-
ment
Step
Adjustment C Tension Lever Adjustment
1
2
Loosen the Tension lever fastening screw.
Apply a tension gauge to the lever, and
firmly tighten the screw at a force of 40
g (.088 lb).
Nominal tension value: 40 g (.088 lb)
Procedure
Adjustment Notes
Procedure
Adjustment Notes
CONFIDENTIAL

Table of Contents

Other manuals for Epson TM-U375

Related product manuals