5-44
5.4.2 Sub-assembly
Sub-assembly A N.E. Detector Unit Assembly
Assem-
bly Step
1
2
3
4
5
Part Name Assembly Procedure
Holder-N.E. detector
Nut
Microswitch
CBB-tite (M2 x 8) x 1
Lever-N.E. detector
N. E. detector cable assembly
Attach the Nut to the Holder-N.E. detector by inserting its curved face
first.
Attach the Microswitch to the Holder-N.E. detector and tighten the
screw.
Place protrusions B of the Lever-N.E. detector onto section A of the
Holder-N.E. detector.
Align the U-shaped grooves with dowels C by turning the Lever-N.E.
detector in the direction of the arrow, with protrusions B as the center.
<Checkpoints>
Verify that the Nut is mounted on the correct place in the correct
direction.
Make sure that the Microswitch is attached in the proper direction.
Connect the N. E. detector cable assembly to the Microswitch.
Route the wires as shown in the figure below.
CONFIDENTIAL