EasyManua.ls Logo

Epson TM-U375 - Disassembly; Removing the Fuse

Epson TM-U375
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-2
5.2 DISASSEMBLY
This section describes disassembly procedures for replacing the following three parts:
Fuse
Print head unit
J guide assembly B (cutter blade)
For other disassembly procedures, refer to Section 5.3,
Printer Mechanism Assembly
, and to Section 5.4,
Whole Unit
Assembly
. The disassembly procedures are basically the reverse of the assembly steps described in these sections.
5.2.1 Removing the Fuse
Disassembly
Step
1
2
3
4
(5)
Disassembly Procedure
Turn over the printer
Remove the screws from the Plate-Base assembly.
Remove the GND plate fastening screw, and release the Plate-Base assembly from the tab of the GND
plate.
Remove the Plate-Base assembly from the Case-Main; then disconnect all connectors connected to the
Plate-Base assembly.
(•Replace the fuse as described in Section 4.2.1,
Fuse replacement
.)
CONFIDENTIAL