4. Faults and diagnostics
4−49
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Example of diagnostic memory entry for error E50
Diagnostic memory data
Value
Byte
Designation
Description Dec Hex Bin
1
2
3
4
5
Days [day]
Hours [h]
Minutes [m]
Seconds [s]
Milliseconds [ms]
Error was reported 22.66 ms after
switching on the power supply (bit 7 in
byte 5 is set if this is the first entry
since Power ON).
0
d
0
d
0
d
22
d
194
d
00
h
00
h
00
h
16
h
C2
h
00000000
b
00000000
b
00000000
b
00010110
b
11000010
b
6 Module code Module code of the CMAX: 176 176
d
B0
h
10110000
b
7 Module position
[Pos]
In this case, the CMAX is CPX module
No. 2.
2
d
02
h
00000010
b
8 Channel number Bit 765 ... 0 Description
100 ... 0 Error in I channel
128
d
81
h
10000001
b
9 Error number [FN] CPX error number: 105 105
d
69
h
01101001
b
10 Following channels Always 0 for the CMAX 0
d
00
h
00000000
b
Tab.4/20: Example of diagnostic memory entry