5. Parameter
5−6
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
The following parameters can be modified despite password
protection:
PNU
Parameter Description of the reason
116 Project identifier reserved for the FCT (synchronisation status).
130 Password Must be writable.
133 System password reserved for the FCT (reset CMAX in the event of Forgot password").
204:05 Number of new
entries
Diagnostic memory display (status value, no parameter).
1173:01 Limit value status Required for the display of the limit values (status value, no para
meter).
Tab.5/4: Parameters that can be written without password
Creating a password
PNU 130 contains the password as a string. The parameter
PNU 1192:04 controls the acceptance and delivers the cur
rent status. To define a password for the CMAX:
1. Write the password in PNU 130, e.g. PNU 130
=My_password".
2. Accept the password into the device data by setting
PNU 1192:04 = 1.
The password
is implemented as a string in CMAX and con
sists of 8 bytes (ASCII code: 32 to 127). This permits upper
and lower case letters, numerals and special characters such