5. Parameter
5−7
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
PNU 1192:04 Accept password
Access Values
Write
= 0: Delete password
= 1: Accept password
Read
= 0: No password set
= 1: Password set and access free
= 2: Password set and access blocked
Tab.5/5: Password access control
The password must be entered when connecting with the FCT
for the first time. It then remains active until the project is
closed in the FCT.
To change it, first enter and delete the old password. Then the
new password can be entered and accepted.
The password cannot be read or
reset. If you forget the pass
word, the CMAX can be completely reset. This not only de
letes the axis data but also the device data. This reset can
only be performed by FCT, not via the PLC.
Information on the password protection can be found in the
CMAX FCT−PlugIn Help and in
the PNU in section 5.4.2 and
PNU 1192 in section 5.4.16.