5. Parameter
5−61
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Jog mode time slow speed
PNU PNU: 534 Index: 1 Max index: 1 Class: Var Data type: int32
Values Unit: Time (index = 9)
Linear drive Semi−rotary drive
Dimension Default Minimum Maximum Dimension Default Minimum Maximum
SI 1 ms 3.000 0 1.000.000 1 ms 3.000 0 1.000.000
Imperial 1 ms 3.000 0 1.000.000 1 ms 3.000 0 1.000.000
Duration of the slow speed phase.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.
Jog mode workpiece mass
PNU PNU: 536 Index: 1 Max index: 1 Class: Var Data type: int32
Values Unit: Mass (index = 5)
Linear drive Semi−rotary drive
Dimension Default Minimum Maximum Dimension Default Minimum Maximum
SI 0.1 kg 0 0 20.000 1 kg cm
2
0 0 2.000
Imperial 1 lb 0 0 4.409 0.1 lb in
2
0 0 6.834
Workpiece mass during jogging.
Depending on PNU 521:01, the corresponding default value is used instead, if necessary.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.