Note: The encoder rotor can only be mated to the encoder shaft in one position. The encoder shaft has 3 flats that
must align correctly to the encoder rotor ID and ribs. See Figure 5.3 for reference.
Step 4
Install the three M4 screws thru encoder and standoff assembly (#17-6) and tighten. Take note not to over tighten.
Step 5
Reconnect encoder ribbon cable to motor controller board. (See section 6 for connector position on motor control
board).