Chapter 5. Communication
110 AT600 User’s Manual
Command 184 (0xB8): Write Digital Configuration (cont.)
Command 185 (0xB9): Write Pulse Configuration
This command is to write the pulse configuration.
Table 79: Response Data Bytes for Write Digital Configuration
Byte Format Description
0 Unsigned-8 Channel Number(1/2)
1 Unsigned-8 Digital Output type:
0: Off; 1: Pulse; 2: Frequency; 3: Alarm;
Table 80: Command-Specific Response Codes for Write Digital Configuration
Code Class Description
0 Success No Command-Specific Errors
1 Undefined
2 Error Invalid Selection
3-4 Undefined
5 Error Too Few Data Bytes Received
6 Error Device-Specific Command Error
7Error In Write Protect Mode
8-15 Undefined
16 Error Access Restricted
8-127 Undefined
Table 81: Request Data Bytes for Write Pulse Configuration
Byte Format Description
0 Unsigned-8 Channel Number(1/2)
1 Unsigned-8 Measurement Type:
5: Forward Batch Total;
6: Reverse Batch Total;
7: Net Batch Total;
2 Unsigned-8 Pulse Value Unit
3 - 6 Float Pulse Value
7 - 10 Unsigned-32 Pulse Time, Unit is ms
11 Unsigned-8 Pulse Error Handling:
2: Hold Good Value;
4: Stop;

Table of Contents