AT600 User’s Manual 111
Chapter 5. Communication
Command 185 (0xB9): Write Pulse Configuration (cont.)
Table 82: Response Data Bytes for Write Pulse Configuration
Byte Format Description
0 Unsigned-8 Channel Number(1/2)
1 Unsigned-8 Measurement Type:
5: Forward Batch Total;
6: Reverse Batch Total;
7: Net Batch Total;
2 Unsigned-8 Pulse Value Unit
3 - 6 Float Pulse Value
7 - 10 Float Pulse Time, Unit is ms
11 Unsigned-8 Pulse Error Handling:
0: Hold Good Value;
1: Stop;
Table 83: Command-Specific Response Codes for Write Pulse Configuration
Code Class Description
0 Success No Command-Specific Errors
1Undefined
2 Error Invalid Selection
3-4 Undefined
5 Error Too Few Data Bytes Received
6 Error Device-Specific Command Error
7Error In Write Protect Mode
8-15 Undefined
16 Error Access Restricted
8-127 Undefined