EasyManua.ls Logo

GE AT600 - Page 148

GE AT600
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5. Communication
136 AT600 User’s Manual
Command 224 (0xE0): Read Error Limits
This command is to read flow meter error limits.
Table 153: Request Data Bytes for Read Error Limits
Byte Format Description
0 Unsigned-8 Error limit:
1. Correlation Peak Limit
2. Acceleration Limit
3. Velocity Low Limit
4. Velocity High Limit
5. Amp Disc Min
6. Amp Disc Max
7. Signal Low Limit
8. Sound Speed Limit
9. Errors Allowed
Table 154: Response Data Bytes for Read Error Limits
Byte Format Description
0 Unsigned-8 Error limit :
1. Correlation Peak Limit
2. Acceleration Limit
3. Velocity Low Limit
4. Velocity High Limit
5. Amp Disc Min
6. Amp Disc Max
7. Signal Low Limit
8. Sound Speed Limit
9. Errors Allowed
1 - 4 float Error limit Value;

Table of Contents

Related product manuals